It is a cost effective, intelligent solar inverter which accept Solar & Utility input at the same time. The comprehensive LCD display offers user-configurable and easy-accessible button adjustment such as battery charging current, AC/solar charger priority and DC priority.When battery voltage low,it will automatically switch to AC grid to supply continuously power to the loads.
ContactFeatures
Off Grid Solar Inverter1-2.4KVA Off-grid solar inverter for Home Power System.
Modified Sine WaveModified sine wave AC output, wide application range.
Inbuilt Solar Charge ControllerInbuilt with 50A MPPT solar charge controller.

LCD/LED Display Information
Figure 1 Top Panel
1. Output Receptacle(s)
2. LCD display
3. Status indicators
4. Settings button
5. POWER switch
LCD/LED Display Information
Figure 2 Top Panel
6. DC Input Wires
7. PV input,note that the polarity is not reversed
8. Input fuse
9. AC input


Solar System Connection
- Rated power:1.2KVA-2.4KVA
- Simulated sine wave inverter
- Built-in 50A MPPT Solar Charge Controller
- MFD (multi-function display)
- 10A or 20A standard charging current from utility
- AC/solar priority for output via MFD
- AC/solar priority for charging via MFD
- 3 steps charging algorithm
- Overload & short-circuit protection
- Battery reverse polarity protection
- Auto restart while AC/solar is recovering
- Adjustable solar and utility charging current
↓↓↓Installation Portfolio------------

Specification
MODEL | Xtreme Solar6+6 | Xtreme Solar 11+11 | ||||
---|---|---|---|---|---|---|
Nominal Battery System Voltage | 12VDC | 24VDC | ||||
INVERTER OUTPUT | ||||||
Rated Power | 1200VA/720W | 2400VA/1440W | ||||
Waveform | Simulated Sine-wave | |||||
Nominal Output Voltage RMS | 230V | |||||
Output Voltage Regulation | +10/-18% | |||||
Output Frequency | 50Hz/60Hz +/-1 Hz | |||||
Inverter Efficiency(Peak) | >80% | |||||
Line Mode Efficiency | >98% | |||||
Typical Transfer Time | Typical 15~20ms 40ms max | |||||
AC INPUT | ||||||
Voltage | 230VAC | |||||
Selectable Voltage Range | Narrow | 170~280VAC | ||||
Selectable Voltage Range | Wide | 90~280VAC | ||||
Frequency Range | 40Hz-70Hz (Auto sensing) | |||||
BATTERY | ||||||
Nominal Input Voltage | 12VDC | 24VDC | ||||
Minimum Start Voltage | 10.5VDC | 21.0VDC | ||||
Low Battery Alarm | 10.4VDC (min) | 20.8VDC (min) | ||||
Low Battery Cutoff | 9.9~12VDC (Can be set) | 19.8~24VDC (Can be set) | ||||
High Voltage Cutoff | 15.0VDC (max) | 30.0VDC (max) | ||||
SOLAR CHARGER & AC CHARGER | ||||||
Maximum PV Charge Current | 50A (max) | |||||
Maximum PV Array Power | 450W/750W | 900W/1500W | ||||
MPPT Range @ Operating Voltage | 16~55VDC | |||||
Maximum PV Array Open Circuit Voltage | 55VDC | |||||
Maximum Efficiency | >95% | |||||
Standby Power Consumption | <2W | |||||
AC Charger Voltage | 14.5(max) | 29(max) | ||||
AC Charging Current | 10A / 20A (Can be set) | |||||
Maximum Charge Current | 10-50A (Can be set) | |||||
BYPASS & PROTECTION | ||||||
Nominal Input Frequency | 40Hz – 70Hz | |||||
Overload Protection (SMPS Load) | FUSE | |||||
Output Short Circuit Protection | FUSE | |||||
Bypass Fuse Rating | 10A | |||||
Max Bypass Current | 10Amp | |||||
MECHANICAL SPECIFICATIONS | ||||||
Machine Dimensions (W*H*D) | 231*290*92mm | |||||
Package Dimensions (W*H*D) | 595*375*315mm | |||||
Net Weight (kg) | 2.8 | 4.0 | ||||
Gross Weight (kg) | 3.5 | 4.7 | ||||
OTHER | ||||||
Operation Temperature Range | 0°C to 50°C | |||||
Audible Noise | 50dB MAX | |||||
Display | LED+LCD | |||||
Loading(20GP/40GP/40HQ) | 1700pcs / 3400pcs / 4100pcs |