EP3300 TLV Series Low Frequnecy Pure Sine Wave Split Phase Inverter Charger (1-6KW)
This split phase inverter EP3300 TLV series, capacity from 1KW-6KW, DC 12V/24V/48V, it’s applicable to 110VAC/120VAC markets demands, which matches AC 110VAC/120V single phase, or two phase 110VAC/120V 120V/240V; In LCD display, you can set output voltage, frequency, charging voltage, charging current to design best use based on different loads applications; meanwhile, you can also connect extra solar charger controller to build a solar home system, take use of sunshine freely and save electricity bills.
Features:
- Pure sine wave output, split phase HOT1+ N + HOT2 available, 120VAC/220VAC
- MFD (multi-function display) & Friendly user interface
- 3 Steps optimizing charge for battery pack
- Overload and short-circuit protection
- Settable: charging/charging current, utility/Battery priority, utility input wide/narrow range
- Inverter voltage can be set to 100V/110V/120V
- Inverter frequency can be set to 50/60Hz
Two Colors Option:
Pure sine wave output
Two pure sine wave AC 110V/120V output(Split Phase)

Smart Battery Chargers – 3 setps optimizing battery charge
Boost CC Stage: If A/C input is applied, the charger will run at full current in CC mode until the charger reaches the boost voltage.
Boost CV Stage: the charger will keep the boost voltage in Boost CV mode until the charge current less 6A continue 1minute or keep the boost voltage time more than 2hours . Then drop the voltage down to the float voltage.
Float Stage: In float mode, the voltage will stay at the float voltage. If the A/C is reconnected , the charger will reset the cycle above.

Easy to read all working modes and parameters in LCD

Line Mode

Input power will provide energy to load directly. And it will charge the battery at the same time.If voltage of input power is outside of section, the machine will switch to battery mode.
Battery Mode
The unit will get energy from battery and provide to load.

Fault Mode

If any fault has happened, the machine will enter to the mode. And fault code is displayed on the LCD.
Smart setting to make inverter work more efficiency
Perfectly driving inductive load current

PRODUCT DETAILS

INVERTER SYSTEM CONNECTION

EP3300 TLV, split phase inverter, it can support different loads with it’s inbuilt pure copper transformer, like laptop, TV, Air-conditioner, fridge etc… Normally this inverter work with battery as back up system to meet different power demands in daily life; it can also connect extra MPPT/PWM solar charge controller, then work as an solar inverter system, use sunshine energy to save electricity bills.
APPLICABLE PLACE

Model | EP33-1012TLV | EP33-1024TLV | EP33-1512TLV | EP33-1524TLV | EP33-2012TLV | EP33-2024TLV | EP33-3024TLV | EP33-3048TLV | EP33-4024TLV | EP33-4048TLV | EP33-5048TLV | EP33-6048TLV |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Inverter Output | ||||||||||||
Rated power(W) | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |||||
Power Factor | 1 | |||||||||||
Wave form | Pure sine wave/ Same as input waveform (bypass mode) | |||||||||||
Output voltage RMS | 100V/110V/120VAC(200V/220V/240VAC)±10% | |||||||||||
Output frequency | 50HZ or 60HZ (±0.3HZ) (can be set) | |||||||||||
Overload protection | Breaker + software protection | |||||||||||
Output short circuit | Breaker + software protection | |||||||||||
Inverter efficiency(peak) | >80% | |||||||||||
Overload | 100%<Load<110% (alarm 5min then stop output and fault code 07); 110%<Load<125% (alarm 60s then stop output and fault code 07); Load>125% (alarm 10s then stop output and fault code 07) | |||||||||||
Surge rating | 3000VA | 4500VA | 6000VA | 9000VA | 12000VA | 15000VA | 18000VA | |||||
Capable of starting electric motor | 1P | 1P | 1.5P | 1.5P | 2P | 3P | ||||||
Battery | ||||||||||||
Battery voltage | 12VDC/24VDC | 24VDC/48VDC | 48VDC | |||||||||
Minimum start voltage | 11VDC/22VDC/44VDC | |||||||||||
Low battery voltage cut off | (low voltage fault code04)10/10.5/11V for 12V model(*2 for 24DVC / *4 for 48VDC) | |||||||||||
Low battery voltage alarm | Add 0.5V/battery: (low battery alarm one second one time) (10/10.5/11V) + 0.5Vdc for 12V model(*2 for 24DVC / *4 for 48VDC) | |||||||||||
High battery voltage alarm | Add +1V/battery: (high voltage one second one time/after 30s fault 03) (13.8-14.5V) + 1V for 12V model(*2 for 24DVC / *4 for 48VDC) | |||||||||||
Save mode | Load≤40W(110V)/80W(220V) | |||||||||||
AC Input Mode | ||||||||||||
Input waveform | Pure sine wave | |||||||||||
Nominal input voltage | 220Vac / 230Vac / 240Vac | |||||||||||
Max input voltage | 270Vac MAX | |||||||||||
Input frequency | 50HZ/60HZ (auto sensing) | |||||||||||
Efficiency(AC mode) | >95% (load, full battery) | |||||||||||
Transfer time AC TO DC | 15ms(max) | |||||||||||
Transfer time DC TO AC | 15ms(max) | |||||||||||
Charge Mode | ||||||||||||
Boost Voltage | 14.1V(Default) Range of adjustment 13.8-14.5V/*2 for 24VDC/*4 for 48VDC (Regulation step 0.1V) | |||||||||||
Float Voltage | 13.5V(default) Range of adjustment 13.5-13.7V/*2 for 24VDC/*4 for 48VDC (Regulation step 0.1V) | |||||||||||
12V | 30A | 45A | 60A | |||||||||
24V | 20A | 25A | 30A | 40A | 60A | |||||||
48V | 20A | 30A | 35A | 40A | ||||||||
Min charge current 10A. change by every 5A. | ||||||||||||
Dimensions | ||||||||||||
Dimensions (W*H*D) | 277*196*466mm | 277*186*621mm | ||||||||||
Ship Dimensions (W*H*D) | 376*306*592mm | 376*296*747mm | ||||||||||
Warranty | One year(standard),2years optional(IP20) |